Buy thermocouples

Thermocouples from JUMO are based on over 50 years of experience in the manufacture of industrial temperature probes and are available as thermocouple types K, J, N, S and B. They reliably measure high temperatures, can be used flexibly in numerous applications, and can be tailored precisely to application-specific requirements. The thermocouples used, which are standardized in German, European and American standards, can be supplemented by other JUMO products, such as transmitters. Buy thermocouple now or request a quote!

  • Product selection guide

Thermocouples

Filter
1
Hits: 17
Screw-in thermocouples - With terminal head form B
H2 Signet

Screw-in thermocouples

With terminal head form B Basic type: 901020
Screw-in thermocouples are primarily used for measuring temperatures in liquids and gases. Their installation type enables the formation of reliable seals, both for vacuum and overpressure applications.
  • Temp.: -200 to +800 °C
  • Insertion length 160 to 600 mm
  • Thermocouples type J, K, and L
Push-in thermocouples - With terminal head form B

Push-in thermocouples

With terminal head form B Basic type: 901120
Push-in thermocouples are predominantly used for measuring temperatures in liquid and gaseous media. Thermowells made of various ceramic materials and heat-resistant steels protect the measuring insert against chemical influences and mechanical damage.
  • Temp.: -200 to +1200 °C
  • Insertion length 100 to 960 mm
  • Thermocouples type B, J, K, L, and S
Push-in thermocouples - With form A terminal head

Push-in thermocouples

With form A terminal head Basic type: 901110
Push-in thermocouples are predominantly used for measuring temperatures in liquid and gaseous media. Thermowells made of various ceramic materials and heat-resistant steels protect the measuring insert against chemical influences and mechanical damage.
  • Temp.: -200 to +1600 °C
  • Protection tube diameter 15 or 22 mm
  • Thermocouples type B, J, K, L, and S
Mineral-insulated thermocouples - According to DIN 43710 and DIN EN 60584 with bare connection wires

Mineral-insulated thermocouples

According to DIN 43710 and DIN EN 60584 with bare connection wires Basic type: 901210
Mineral-insulated thermocouples are made of a flexible, thin-walled sheath cable in which the thermocouple wires are embedded in compressed fire-resistant magnesium oxide. The good thermal transfer between the sheath and the thermocouple enables short response times and high measuring accuracy.
  • Temp.: -200 to +1200 °C
  • Thermocouples type J, K, L, N
  • Response time: t0.5 from 0.15 s
Mineral-insulated thermocouples - According to DIN 43710 and DIN EN 60584 with standard tab connector

Mineral-insulated thermocouples

According to DIN 43710 and DIN EN 60584 with standard tab connector Basic type: 901240
Mineral-insulated thermocouples are made of a flexible, thin-walled sheath cable in which the thermocouple wires are embedded in compressed fire-resistant magnesium oxide. The good thermal transfer between the sheath and the thermocouple enables short response times and high measuring accuracy.
  • Temp.: -200 to +1200 °C
  • With standard tab connector
  • Response time: t0.5 from 0.15 s
Mineral-insulated thermocouples - According to DIN 43710 and DIN EN 60584 with terminal head form B

Mineral-insulated thermocouples

According to DIN 43710 and DIN EN 60584 with terminal head form B Basic type: 901220
Mineral-insulated thermocouples are made of a flexible, thin-walled sheath cable in which the thermocouple wires are embedded in compressed fire-resistant magnesium oxide. The good thermal transfer between the sheath and the thermocouple enables short response times and high measuring accuracy.
  • Temp.: -200 to +1200 °C
  • With terminal head B
  • Response time: t0.5 from 0.15 s
Screw-in thermocouples - With compensating cable

Screw-in thermocouples

With compensating cable Basic type: 901050
Screw-in thermocouples are primarily used for measuring temperatures in liquids and gases. Depending on the version, the compensating cables are suitable for dry or humid rooms that have a temperature range from -20 to +350 °C.
  • Temp.: -200 to +600 °C
  • Stainless steel 1.4571
  • Thermocouples type K and L
Mineral-insulated thermocouples - According to DIN 43710 and DIN EN 60584 with terminal head form J

Mineral-insulated thermocouples

According to DIN 43710 and DIN EN 60584 with terminal head form J Basic type: 901230
Mineral-insulated thermocouples are made of a flexible, thin-walled sheath cable in which the thermocouple wires are embedded in compressed fire-resistant magnesium oxide. The good thermal transfer between the sheath and the thermocouple enables short response times and high measuring accuracy.
  • Temp.: -200 to +1200 °C
  • With terminal head J
  • Response time: t0.5 from 0.15 s
Push-in thermocouples - With bayonet fastener

Push-in thermocouples

With bayonet fastener Basic type: 901190
Push-in thermocouples with a bayonet fastener are predominantly used for temperature measurement in solid bodies, friction bearings, and tools (e.g. in the plastics industry). The special shape of the probe tip makes these temperature probes suitable for use in flat and pointed drilled holes.
  • Temp.: 0 to 400 °C
  • Compensating cable Silicone/PTFE/metal braiding
  • Thermocouples type J, K, and L
JUMO FOODtemp - Food insertion thermocouples

JUMO FOODtemp

Food insertion thermocouples Basic type: 901350
Due to their special construction, these robust, steam-tight food insertion thermocouples are especially suited to cooking, boiling, and baking processes in all food processing and food preservation applications. The stainless steel probe tube is available with a concentric or oblique probe tip.
  • Temp.: -100 to +260 °C
  • Suitable for the food industry
  • Thermocouple type K
Thermocouples - For devices and plants tested according to DIN EN 14597

Thermocouples

For devices and plants tested according to DIN EN 14597 Basic type: 901006
Screw-in thermocouples are predominantly used for measuring temperature in liquids and gases. Protection tubes made of various materials protect the measuring insert against chemical influences and mechanical damage.
  • Temp.: -35 to +1500 °C
  • Stainless steel 1.4571
  • Thermocouples type B, K, L, and S
Mineral-insulated thermocouples - According to DIN 43710 and DIN EN 60584 with compensating cable

Mineral-insulated thermocouples

According to DIN 43710 and DIN EN 60584 with compensating cable Basic type: 901250
Mineral-insulated thermocouples are made of a flexible, thin-walled sheath cable in which the thermocouple wires are embedded in compressed fire-resistant magnesium oxide. The thermal transfer between the sheath and the thermocouple enables short response times and high measuring accuracy. A compression fitting allows mineral-insulated thermocouples for hydrogen applications up to over 1000 bar.
  • Temp.: -200 to +1200 °C
  • Thermocouples J, K, L
  • Response time: t0.5 from 0.15 s
Push-in thermocouples - With compensating cable

Push-in thermocouples

With compensating cable Basic type: 901150
Push-in thermocouples are predominantly used for temperature measurement in solid bodies (e.g. heating plates and sealing jaws). The compensation cable is relieved of strain at the transition to the protection tube. Bend protection is available as an option.
  • Temp.: -50 to +600 °C
  • Stainless steel 1.4571
  • Thermocouples type J, K, and L
Screw-in thermocouples - With terminal head form J
H2 Signet

Screw-in thermocouples

With terminal head form J Basic type: 901030
Screw-in thermocouples are primarily used for measuring temperatures in liquids and gases. Their installation type enables the formation of reliable seals, both for vacuum and overpressure applications.
  • Temp.: -200 to +800 °C
  • Insertion length 50 to 300 mm
  • Thermocouples type J, K, and L
Screw-in melt thermocouples - With sharp or flat probe tips

Screw-in melt thermocouples

With sharp or flat probe tips Basic type: 901090
Screw-in melt thermocouples are predominantly used to acquire temperature measurements for melt temperatures in the plastics industry. Sharp or flat probe tips ensure optimum temperature acquisition depending on the requirements.
  • Temp.: -40 to +600 °C
  • Ceramic insulated probe tip
  • Thermocouples type J, K, and L
JUMO TDA-300 and JUMO TDA-3000 - Handheld thermometer

JUMO TDA-300 and JUMO TDA-3000

Handheld thermometer Basic type: 702540
The TDA-300 and TDA-3000 are portable digital temperature display devices. They are used in conjunction with precision thermocouples or precision RTD temperature probes for temperature measurement on surfaces, in liquids, in melts, and in plastic materials.
  • Replaceable probes
  • RTD temperature probe and thermocouples
  • Battery operating life 400 hours
Precision indicating device - Test equipment for temperature and its traceability

Precision indicating device

Test equipment for temperature and its traceability Basic type: 902722
The product is for monitoring all temperature measurement technology that is used for industrial applications, building technology, and quality assurance. It ensures that the measurement results can be traced back to the national standards.
  • Precision indicating device
  • RTD temperature probe / thermocouple
  • Measuring range: -200 to +1200 °C

item items, maximum number of items reached

Purchase thermocouples

The most important background information